GasspeicherGermany · GIE AGSI+

Scenario calculation · Germany · as of gas day 17 November 2026provisional report

Gas storage forecast: how long will the gas last?

Lowest level (middle)
10.1%07/03/2027
Below 30%
17/01/2027in 10 of 10 scenarios
On 1 February
19.3%Range 12.1%-44.2%

If the withdrawal of the winters since 2016/17 is applied to today's stock of 141.2 TWh, the fill level in the middle of the scenarios falls to 10.1% by 7 March 2027. In 10 of 10 scenarios it falls below 30% before the end of April, in 6 below 20%.

Calculation model, not a prediction: this winter's weather, imports and consumption are unknown. Starting value 57.1% on 17 November 2026 (GIE AGSI+).

Fill level until the end of April: 10 winters as scenarios

Each scenario applies the daily injection and withdrawal of an earlier winter to today's stock. Choose a comparison winter and set consumption and imports.

Fill level : actual and scenarios until the end of AprilMiddle of the 10 scenarios with the range from the most favourable to the least favourable comparison winter, actual curve since 1 October and previous year.0%20%30%50%75%100%OctNovDecJanFebMarApr30%: filling target per storage facility on 1 February

Choose a day: move the mouse over the chart, tap it, or use the arrow keys.

  • Actual since 1 October
  • Middle of the scenarios
  • Range of all scenarios
  • Previous year
What will the winter be like?
Mild and cold: in each case the three comparison winters with the lowest and the highest withdrawal from November to February.
Or exactly like an earlier winter
Gas consumption
Compared with the comparison winter, based on up to 3.7 TWh of consumption on a winter day. Lower consumption spares the storage.
Imports
Per day compared with the comparison winter. 0.1 TWh a day corresponds to roughly one LNG tanker cargo every ten days. More imports spare the storage.

The scenarios in detail

Sorted from the mildest to the coldest comparison winter (measured by withdrawal from November to February). Without any change to consumption and imports.

Like winterLowest levelonBelow 30%Below 20%1 February
2019/20 mild29.9%03/04/202703/04/2027never44.2%
2022/23 mild21.2%17/03/202714/02/2027never35.8%
2018/19 mild26.7%01/03/202704/02/2027never31.0%
2023/24 average21.3%04/04/202706/02/2027never30.7%
2021/22 average6.0%18/03/202710/01/202720/01/202713.3%
2025/26 average9.7%25/02/202710/01/202724/01/202714.5%
2020/21 average4.9%25/03/202709/01/202718/01/202713.1%
2024/25 cold4.5%20/03/202708/01/202716/01/202712.1%
2017/18 cold5.5%02/04/202710/01/202702/02/202720.4%
2016/17 cold9.4%10/03/202717/01/202729/01/202718.2%

How the model calculates

Starting point is the latest storage level reported by GIE AGSI+ for Germany: 141.2 TWh of 247.4 TWh working gas (57.1%).

Scenarios: For each winter since 2016/17, the model applies its daily net injection and withdrawal, starting from the same calendar day, to today's stock. The winters stand for different weather, different imports and different consumption - just as they actually occurred.

Adjustment to the present: The withdrawal of a comparison winter is scaled by the ratio of actual withdrawal over the last 30 days to that of the comparison winter in the same period (at most halved or doubled). The influence fades over the following months.

Technical limit: The emptier a storage facility, the less gas it can deliver per day. Daily withdrawal is therefore capped at the highest withdrawal ever observed at the same fill level.

Backtest: At 80 starting points from October to February in the winters 2017/18 to 2025/26 (each time excluding the winter itself), the middle of the scenarios was off by an average of 3.5 percentage points after 30 days, 7.0 after 60, 10.7 after 90 and 12.8 after 120 days. The actual path lay within the range in 83% of cases.

Consumption and imports: The two controls work in opposite directions. Extra consumption is additionally withdrawn from storage every day (annual consumption 904 TWh according to GIE AGSI+, distributed by month), while additional imports flow in on top. Both apply relative to the respective comparison winter; the technical withdrawal limit remains.

What the model cannot do: It knows neither the weather forecast nor prices, import plans or political measures. If a scenario falls very low, this does not mean the gas runs out: in practice, the market and the authorities react beforehand, for example with more imports, savings or the early warning and alert level of the gas emergency plan. A value close to 0% only shows that the winter could not be covered from storage with today's stock.

All countries: The country selector above shows the same calculation for every country with its own storage facilities and for the EU as a whole. Comparison winters, adjustment and backtest are calculated per country from its own data.

Data: GIE AGSI+, Germany, daily values since 2016. Recalculated daily after each new gas day.